Dimensional Metrology

Dimensional
Calibration

Length, diameter, depth and form — we calibrate the micrometers, calipers and gauges your work depends on, to sub-micron uncertainty under ISO/IEC 17025.

ISO/IEC 17025 SAC-SINGLAS Accredited Sub-Micron Accuracy
01 23 45 67 89 10 cm 0.02 mm 0 5 10 MEASURING JAWS VERNIER SCALE · 0.02 MM CALIBRATED 0 – 1000 MM
0.2 µm
Finest CMC uncertainty
0
Instrument types in scope
0.2 µm
Finest CMC uncertainty
0 mm
Maximum range

Accredited Scope

Find Your Instrument

Every instrument below sits within our SAC-SINGLAS accredited dimensional scope. Type a name or filter by category to check coverage, range and uncertainty.

Showing 25 of 25 instrument types
InstrumentRangeCMC Uncertainty
External Micrometer0–1000 mm0.2–7.0 µm
Inside Micrometer (2-leg)5–125 mm1.0–3.0 µm
Internal Micrometer0–400 mm2.0–4.0 µm
Depth Micrometer0–150 mm3.0 µm
Caliper (Dial / Vernier / Digimatic)0–1000 mm4.0–10 µm
Height Gauge0–600 mm2.0–20 µm
Depth Gauge0–600 mm0.50–10 µm
Caliper Checker0–600 mm0.50–4.3 µm
Caliper Gauge0–70 mm5.0 µm
Bore Gauge0–290 mm1.0–2.0 µm
Plain Plug / Pin Gauge0–22 mm0.5 µm
Thread Plug Gauge0–20 mm2.0 µm
Feeler GaugeUp to 1 mm0.40 µm
Thickness Gauge0–12 mm1.0 µm
Coating / UT Thickness Gauge0–2 mm0.5–9.0 µm
Dial Gauge Calibrator0–100 mm0.20–0.60 µm
Linear Indicating Gauge0–100 mm0.30–1.1 µm
Lever Indicating Gauge / DTI0–0.8 mm0.30–2.80 µm
Comparator Stand0–300 mm3.0 µm
End Standards / Setting Rods25–1000 mm0.40–6.9 µm
Optical Measuring Instruments0–300 mm0.50–1.9 µm
Glass Scale / Steel Rule0–300 mm0.60–3.3 µm
Geometrical Measurement0–300 mm0.30–0.60 µm
Roughness Tester / Specimen0.4–3.2 µm0.065 µm
Straightedge0–1000 mm3.0 µm
No match in this list — but our scope may still cover it. Ask us directly →

View full accredited scope →

Who We Work With

Industries We Serve

Aerospace & MRO Precision Engineering / CNC Oil & Gas Manufacturing Automotive Semiconductor Medical Devices Marine & Shipyard

How It Works

Our Calibration Process

Every calibration follows a structured, documented process to ensure consistency and traceability.

1

Receive & Inspect

Your instrument is logged, inspected for damage, and assigned a job number.

2

Calibrate

Calibrated against traceable reference standards by our qualified engineers.

3

Report & Return

Calibration certificate issued with full measurement data and uncertainty values.

Need Dimensional Calibration?

Send us your instrument list and we'll provide a detailed quote within 1 business day.